MATERIEL MEDICAL NEUF & RECONDITIONNÉ Sale 231130

RESPIRATEUR D'ANESTHESIE GENERAL ELECTRIC AVANCE CS2 avec MONITORING CARESCAPE D'ANESTHESIE

L'enchère commencera dans __ jours et __ heures

Prix ​​de départ: €3,000

Estimation: €15,000

T.V.A.: Sur commission seulement

VENTILATOR OPERATING SPECIFICATIONS • Ventilator parameter ranges • Tidal volume range: 5 to 1500ml ( Volume Control, PCV-VG and SIMV volume 20 to 1500ml) (PCV modes 5 to 1500ml) • Incremental settings: 20 to 50 mL (increments of 1 mL) • 50 to 100 mL (increments of 5 mL) • 100 to 300 mL (increments of 10 mL) • 300 to 1000 mL (increments of 25 mL) • 1000 to 1500 mL (increments of 50 mL) • Minute volume range: Less than 0.1 to 99.9 L/min • Pressure (Pinspired) range: 5 to 60 cmH2O (increments of 1 cmH2O) 5 to 1500 mL volume delivery • Pressure (Pmax) range: 12 to 100 cmH2O (increments of 1 cmH2O) • Pressure (Psupport) range: Off, 2 to 40 cmH2O (increments of 1 cmH2O) • Rate: 4 to 100 breaths per minute for • Volume Control and Pressure • Control; 2 to 60 breaths per minute for SIMV, PSVPro and SIMV PCV-VG; 4 to 60 bpm for CPAP+PSV (increments of 1 breath per minute) • Inspiratory/ expiratory ratio: 2:1 to 1:8 (increments of 0.5) • Inspiratory time: 0.2 to 5.0 seconds (increments of 0.1 seconds) (SIMV, PSVPro and CPAP PSV) • Trigger window: 0 to 80% (increments of 5%) • Flow trigger: 1 to 10 L/min (increments of 0.5 L/min) • 0.2 to 1 L/min (increments of 0.2 L/min) • Inspiration • termination level: 5 to 75% (increments of 5%) • Inspiratory Pause range: 0-60% • Positive End Expiratory Pressure (PEEP) • Type: Integrated, electronically • controlled • Range: OFF, 4 to 30 cmH2O (increments of 1 cmH2O) • Ventilator performance • Pressure range at inlet: 240 kPa to 700 kPa (35 psig to 100 psig) • Peak gas flow: 120 L/min + fresh gas flow • Flow valve range: 1 to 120 L/min • Flow compensation range: 150 mL/min to 15 L/min • Ventilator Accuracy • Delivery/monitoring accuracy • Volume delivery: > 210 mL = better than 7% • ≤ 210 mL = better than 15 mL • < 60 mL = better than 10 mL • Pressure delivery: ±10% or ±3 cmH2O • PEEP delivery: ±1.5 cmH2O • Volume monitoring: > 210 mL = better than 9% • ≤ 210 mL = better than 18 mL • < 60 mL = better than 10 mL • Pressure monitoring: ±5% or ±2 cmH2O • ALARM SETTINGS • Tidal volume (VTE): Low: OFF, 1 to 1500 mL • High: 20 to 1600 mL, OFF • Minute volume (VE): Low: OFF, 0.1 to 10 L/min • High: 0.5 to 30 L/min, OFF • Inspired oxygen (FiO2): Low: 18 to 99% • High: 19 to 100%, OFF • Apnea alarm: Mechanical ventilation ON: • < 5 mL breath measured in 30 seconds • Mechanical ventilation OFF: • < 5 mL breath measured in 30 seconds • Low airway pressure: 4 cmH2O above PEEP • High pressure: 12 to 100 cmH2O (increments of 1 cmH2O) • Sustained airway pressure: Mechanical ventilation ON: • Pmax < 30 cmH2O, the sustained limit is 6 cmH2O • Pmax 30 to 60 cmH2O, the sustained limit is 20% of Pmax • Pmax > 60 cmH2O, the sustained limit is 12 cmH2O • PEEP and mechanical ventilation ON • Sustained limit increases by PEEP minus 2 cmH2O • Mechanical ventilation OFF: • Pmax ≤ 60 cmH2O, the sustained limit is 50% of Pmax • Pmax > 60 cmH2O, the sustained limit is 30 cmH2O • Subatmospheric pressure: Paw < -10 cmH2O • Audio pause countdown clock: 120 to 0 seconds • Ventilator Components Flow transducer • Type: Variable orifice flow sensor • Dimensions: 22 mm OD and 15 mm ID • Location: Inspiratory outlet and expiratory inlet • Ventilator screen • Display size: 15 inch • Pixel format: 1024 x 768 • Battery backup • Backup power: Demonstrated battery time is up to 90 minutes when fully charged. • Battery time under extreme conditions is 30 minutes. • Battery type: Internal rechargeable sealed lead acid • Communication ports • RS-232C compatible serial interface • Ethernet • Datex-Ohmeda device interface solutions port • USB port • VGA Output • Anesthetic Agent Delivery • Delivery Vaporizers: Tec* 6 Plus, Tec 7 • Number of positions: 2 (3 as an option) • Mounting: Tool-free installation Selectatec* manifold interlocks and isolates vaporizers • Airway Modules • General • M-CAiO, M-CAiOV, M-CAiOVX module software • version 3.2 or higher; E-CAiO, ECAiOV, E-CAiOVX • • Size (WxDxH): 75 x 228 x 112 mm/ 3.0 x 9.0 x 4.4 in • Weight: 1.6 kg/3.5 lb • Sampling rate: 200 mL/min ±20 mL E-sCAiO, E-sCAiOV • Size (WxDxH): 38 x 205 x 113 mm/1.5 x 8.1 x 4.4 in • Weight: 0.7 kg/1.5 lb • Sampling rate: 120 mL/min ±20 mL • Automatic compensation for atmospheric pressure variation (500 to 800 mmHg for E-, M-series modules; 495 to 795mmHg for CARESCAPE modules) temperature and CO2/N2O and CO2/O2 collision broadening effect. Parameter display update interval typically breath-by-breath. Functional alarms for blocked sample line, D-fend check and D-fend replacement. • Non-disturbing gases: • Ethanol, acetone, methane, nitrogen, nitric oxide, carbon monoxide, water vapor: • Maximum effect on readings: CO2 < 0.2 vol %; O2, N2O < 2 vol % • Carbon dioxide (CO2) • EtCO2: End-tidal CO2 concentration • FiCO2: Inspired CO2 concentration • CO2 waveform • Measurement range: 0 to 15% (0 to 15 kPa, 0 to 113 mmHg) • Accuracy: ±0.2 vol % + 2 % of reading • Datex-Ohmeda infrared sensor • Adjustable low and high alarm limits for EtCO2 and FiCO2 • Respiration rate (RR) • Measurement range: 4 to 60 breaths/min for E-, M-series modules 4 to 100 breaths/min for CARESCAPE modules • Detection criteria: 1% variation in CO2 • Adjustable low and high alarm limits for respiration rate; alarm for apnea • Patient Oxygen (O2) • FiO2: Inspired O2 concentration • EtO2: End-tidal O2 concentration • FiO2-EtO2: Inspired-expired difference • O2 Measurement • Measurement range: 0 to 100% • Accuracy: ±1 vol % +2 % of reading • Datex-Ohmeda differential paramagnetic sensor • Adjustable low and high alarm limits for FiO2 and EtO2; alarm for FiO2 < 18% • Nitrous Oxide (N2O) • Measurement range: 0 to 100% • Accuracy: ±2 vol % +2 % of reading • Anesthetic Agent (AA) • Halothane, Isoflurane, Enflurane • Measurement range: 0 to 6% • Accuracy: ±(0.15 vol% +5% of reading) • SEVOFLURANE • Measurement range: 0 to 8% • Accuracy: ±(0.15 vol% +5% of reading) • Desflurane • Measurement range: 0 to 20% • Accuracy: ±(0.15 vol% +5% of reading) • Waveform displayed • MAC value displayed • Identification threshold: 0.15 vol %1 • Agent mixture detection • Adjustable high and low alarm limits for EtAA, FiAA • Patient Spirometry* • Pressure-volume loop • Pressure-flow loop • Flow-volume loop • Airway pressure and flow waveforms • Adjustable low and high alarm limits for Ppeak, PEEPtot and • MVexp • Alarms for MVexp << MVinsp and for MVexp low. Detection through D-lite* or Pedi-lite* flow sensor and gas sampler with following specifications: • Compact Airway Modules • D-lite Pedi-lite • Respiration rate: 4 to 35 4 to 50 breaths/min breaths/min • Tidal volume • Measurement range: 150 to 15 to 2000 mL 300 mL Accuracy1: ±6% or 30 mL ±6% or 4 mL • Minute volume • Measurement range: 2 to 20 L/min 0.5 to 5 L/min • Accuracy1: ±6% ±6% • Airway pressure • Measurement range: -20 to +100 cmH2O • Accuracy1: ±1 cmH2O • Display units: cmH2O, mmHg, kPa, mbar, hPa Flow • Measurement range: 1.5 to 0.25 to 25 L/min100 L/mi I:E • Measurement range: 1:4.5 to 2:1 • Compliance • Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O Airway resistance • Measurement range: 0 to 40 cmH2O/L/s • CARESCAPE Airway Modules D-lite(+) Pedi-lite(-) • Respiration rate: 4 to 35 4 to 70 breaths/min breaths/min • Tidal volume • • Measurement range: 150 to 5 to 2000 mL 300 mL • Accuracy1: ±6% or 30 mL ±6% or 4 mL • Minute volume • Measurement range: 2 to 20 L/min 0.1 to 5 L/min • Accuracy1: ±6% ±6% • Airway pressure • Measurement range: -20 to +100 cmH2O • Accuracy1: ±1 cmH2O • Display units: cmH2O, mmHg, kPa, mbar, hPa Flow • Measurement range: -100 to -25 to 25 L/min 100 L/min I:E • Measurement range: 1:4.5 to 2:1 • Compliance • Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O • Airway resistance • Measurement range: 0 to 200 cmH2O/L/s • Sensor specifications D-lite/ Pedi-lite/ • at 10 L/min: 1.0 cmH2O