NEW & REFURBISHED MEDICAL EQUIPMENT sale 240409

GENERAL ELECTRIC ADVANCE CS2 ANESTHESIA RESPIRATOR with MONITORING ANESTHESIA CARESCAPE

La subasta comenzará en __ días y __ horas

Precio base: €2,000

Precio estimado: €16,000 - €18,000

IVA: Solo sobre comisión

Features: • 15-inch touchscreen with CARESCAPETM-inspired user interface for a unified Carestation experience. • The ecoFLOW system provides valuable information to help clinicians maintain the desired inspired oxygen concentration during low flow anesthesia. • ecoFLOW allows visualization of agent consumption, helping to avoid unnecessary over-administration of fresh gas flow. • User- configurable quick selections for convenient use of FiO2 and total flow combinations. ecoFLOW benefits: • For the patient : Improves care by providing data on target inspired oxygen concentration. • Economical : Less agent used means less expense, which can have a positive impact on your bottom line by reducing gas waste. • Eco-friendly : Efficient, low flow helps reduce agent and gas waste. Exceptional design: • Central brake for easy handling. • Mounting rails on the top shelf for optimal organization. • Metal work surface for increased durability. • Movable display arm for convenient indoor and outdoor positioning. • Two or three positions for vaporizers, offering flexibility of use. • Two-level work surface lighting for better visibility. The General Electric Avance CS2 is a sophisticated, digital anesthesia delivery system that offers an intuitive, touchscreen user interface. It is equipped with a 15-inch touchscreen with a CARESCAPE TM-inspired user interface for a unified user experience. The system features ecoFLOW technology that provides information that can help clinicians maintain their desired inspired oxygen concentration during low and minimal flow anesthesia. ecoFLOW also allows visualization of agent consumption and helps mitigate wasted overdistribution of fresh gas flow. Clinicians can configure “Quick Picks” for rapid selection of FiO2 and total flow combinations. Ventilator Operating Specifications Ventilator parameter ranges Tidal volume range: 5 to 1500ml (Volume Control, PCV-VG and SIMV volume 20 to 1500ml) (PCV modes 5 to 1500ml) Incremental settings: 20 to 50 mL (increments of 1 mL) 50 to 100 mL (increments of 5 mL) 100 to 300 mL (increments of 10 mL) 300 to 1000 mL (increments of 25 mL) 1000 to 1500 mL (increments of 50 mL) Minute volume range: Less than 0.1 to 99.9 L/min Pressure (Pinspired) range: 5 to 60 cmH2O (increments of 1 cmH2O) 5 to 1500 mL delivery volume Pressure (Pmax) range: 12 to 100 cmH2O (increments of 1 cmH2O) Pressure (Psupport) range: Off, 2 to 40 cmH2O (increments of 1 cmH2O) Rate: 4 to 100 breaths per minute for Volume Control and Pressure Control; 2 to 60 breaths per minute for SIMV, PSVPro and SIMV PCV-VG; 4 to 60 bpm for CPAP+PSV (increments of 1 breath per minute) Inspiratory/ expiratory ratio: 2:1 to 1:8 (increments of 0.5) Inspiratory time: 0.2 to 5.0 seconds (increments of 0.1 seconds) (SIMV, PSVPro and CPAP PSV) Trigger window: 0 to 80% (increments of 5%) Flow trigger: 1 to 10 L/min (increments of 0.5 L/min) 0.2 to 1 L/min (increments of 0.2 L/min) Inspiration termination level: 5 to 75% (increments of 5%) Inspiratory Pause range: 0-60% Positive End Expiratory Pressure (PEEP) Type: Integrated, electronically controlled Range: OFF, 4 to 30 cmH2O (increments of 1 cmH2O) Fan performance Pressure range at inlet: 240 kPa to 700 kPa (35 psig to 100 psig) Peak gas flow: 120 L/min + fresh gas flow Flow valve range: 1 to 120 L/min Flow compensation range: 150 mL/min to 15 L/min Ventilator Accuracy Delivery/monitoring accuracy Volume delivery: > 210 mL = better than 7% ≤ 210 mL = better than 15 mL < 60 mL = better than 10 mL Pressure delivery: ±10% or ±3 cmH2O PEEP delivery: ±1.5 cmH2O Volume monitoring: > 210 mL = better than 9% ≤ 210 mL = better than 18 mL < 60 mL = better than 10 mL Pressure monitoring: ±5% or ±2 cmH2O ALARM SETTINGS Tidal volume (VTE): Low: OFF, 1 to 1500 mL High: 20 to 1600 mL, OFF Minute volume (VE): Low: OFF, 0.1 to 10 L/min High: 0.5 to 30 L/min, OFF Inspired oxygen (FiO2): Low: 18 to 99% High: 19 to 100%, OFF Apnea alarm: Mechanical ventilation ON: < 5 mL breath measured in 30 seconds Mechanical ventilation OFF: < 5 mL breath measured in 30 seconds Low airway pressure: 4 cmH2O above PEEP High pressure: 12 to 100 cmH2O (increments of 1 cmH2O) Sustained airway pressure: Mechanical ventilation ON: Pmax < 30 cmH2O, the sustained limit is 6 cmH2O Pmax 30 to 60 cmH2O, the sustained limit is 20% of Pmax Pmax > 60 cmH2O, the sustained limit is 12 cmH2O PEEP and mechanics ventilation ON Sustained limit increases by PEEP minus 2 cmH2O Mechanical ventilation OFF: Pmax ≤ 60 cmH2O, the sustained limit is 50% of Pmax Pmax > 60 cmH2O, the sustained limit is 30 cmH2O Subatmospheric pressure: Paw < -10 cmH2O Audio pause countdown clock: 120 to 0 seconds Ventilator Components Flow transducer Type: Variable orifice flow sensor Dimensions: 22mm OD and 15mm ID Location: Inspiratory outlet and expiratory inlet Ventilator screen Display size: 15 inch Pixel format: 1024 x 768 Battery backup Backup power: Demonstrated battery time is up to 90 minutes when fully charged. Battery time under extreme conditions is 30 minutes. Battery type: Internal rechargeable sealed lead acid Communication ports RS-232C compatible serial interface Ethernet Datex-Ohmeda device interface solutions port USB port VGA Output Anesthetic Agent Delivery Delivery Vaporizers: Tec* 6 Plus, Tec 7 Number of positions: 2 (3 as an option) Mounting: Tool-free installation Selectatec* manifold interlocks and isolate vaporizers Airway Modules General M-CAiO, M-CAiOV, M-CAiOVX module software version 3.2 or higher; E-CAiO, ECAiOV, E-CAiOVX Size (WxDxH): 75 x 228 x 112 mm/ 3.0 x 9.0 x 4.4 in Weight: 1.6 kg/3.5 lb Sampling rate: 200 mL/min ±20 mL E-sCAiO, E-sCAiOV Size (WxDxH): 38 x 205 x 113 mm/ 1.5 x 8.1 x 4.4 in Weight: 0.7 kg/1.5 lb Sampling rate: 120 mL/min ±20 mL Automatic compensation for atmospheric pressure variation (500 to 800 mmHg for E-, M-series modules; 495 to 795 mmHg for CARESCAPE modules) temperature and CO2/N2O and CO2/O2 collision broadening effect. Parameter display update interval typically breath-by-breath. Functional alarms for blocked sample line, D-fend check and D-fend replacement. Non-disturbing gases: Ethanol, acetone, methane, nitrogen, nitric oxide, carbon monoxide, water vapor: Maximum effect on readings: CO2 < 0.2 vol %; O2, N2O < 2 vol% Carbon dioxide (CO2) EtCO2: End-tidal CO2 concentration FiCO2: Inspired CO2 concentration CO2 waveform Measurement range: 0 to 15% (0 to 15 kPa, 0 to 113 mmHg) Accuracy: ±0.2 vol % + 2 % of reading Datex-Ohmeda infrared sensor Adjustable low and high alarm limits for EtCO2 and FiCO2 Respiration rate (RR) Measurement range: 4 to 60 breaths/min for E-, M-series modules 4 to 100 breaths/min for CARESCAPE modules Detection criteria: 1% variation in CO2 Adjustable low and high alarm limits for respiration rate; alarm for apnea Patient Oxygen (O2) FiO2: Inspired O2 concentration EtO2: End-tidal O2 concentration FiO2-EtO2: Inspired-expired difference O2 Measurement Measurement range: 0 to 100% Accuracy: ±1 vol % +2 % of reading Datex-Ohmeda differential paramagnetic sensor Adjustable low and high alarm limits for FiO2 and EtO2; alarm for FiO2 < 18% Nitrous Oxide (N2O) Measurement range: 0 to 100% Accuracy: ±2 vol % +2 % of reading Anesthetic Agent (AA) Halothane, Isoflurane, Enflurane Measurement range: 0 to 6% Accuracy: ±(0.15 vol% +5% of reading) SEVOFLURANE Measurement range: 0 to 8% Accuracy: ±(0.15 vol% +5% of reading) Desflurane Measurement range: 0 to 20% Accuracy: ±(0.15 vol% +5% of reading) Waveform displayed MAC value displayed Identification threshold: 0.15 vol %1 Agent mixture detection Adjustable high and low alarm limits for EtAA, FiAA Patient Spirometry* Pressure-volume loop Pressure flow loop Flow-volume loop Airway pressure and flow waveforms Adjustable low and high alarm limits for Ppeak, PEEPtot and MVexp Alarms for MVexp << MVinsp and for MVexp low. Detection through D-lite* or Pedi-lite* flow sensor and gas sampler with following specifications: Compact Airway Modules D-lite Pedi-lite Breathing rate: 4 to 35 4 to 50 breaths/min breaths/min Tidal volume Measurement range: 150 to 15 to 2000 mL 300 mL Accuracy1: ±6% or 30 mL ±6% or 4 mL Minute volume Measurement range: 2 to 20 L/min 0.5 to 5 L/min Accuracy1: ±6% ±6% Airway pressure Measurement range: -20 to +100 cmH2O Accuracy1: ±1 cmH2O Display units: cmH2O, mmHg, kPa, mbar, hPa Flow Measurement range: 1.5 to 0.25 to 25 L/min 100 L/mi IE Measurement range: 1:4.5 to 2:1 Compliance Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O Airway resistance Measurement range: 0 to 40 cmH2O/L/s CARESCAPE Airway Modules D-lite(+) Pedi-lite(-) Breathing rate: 4 to 35 4 to 70 breaths/min breaths/min Tidal volume Measurement range: 150 to 5 to 2000 mL 300 mL Accuracy1: ±6% or 30 mL ±6% or 4 mL Minute volume Measurement range: 2 to 20 L/min 0.1 to 5 L/min Accuracy1: ±6% ±6% Airway pressure Measurement range: -20 to +100 cmH2O Accuracy1: ±1 cmH2O Display units: cmH2O, mmHg, kPa, mbar, hPa Flow Measurement range: -100 to -25 to 25 L/min 100 L/min IE Measurement range: 1:4.5 to 2:1 Compliance Measurement range: 4 to 100 1 to 100 mL/cmH2O mL/cmH2O Airway resistance Measurement range: 0 to 200 cmH2O/L/s Sensor specifications D-lite/ Pedi-lite/ D-lite(+) Pedi-lite(+) Dead space: 9.5 mL 2.5 mL Resistance at 30 L/min: 0.5 cmH2O at 10 L/min: 1.0 cmH2O