NEW & REFURBISHED MEDICAL EQUIPMENT sale 240718

SYRINGE PUMP, TOVAMED HK400III, NEW, IN BOX

Die Auktion beginnt in __ Tagen und __ Stunden

Start Preis: €150

Geschätzer Preis: €250 - €450

MwSt: Nur auf Kommission

• Large color LCD screen

• Historical recording

• RS232 interface

• Adjustable horn volume

• Anti-bolus function

• TIVA mode

• 90° rotating pole clamp, practical for horizontal bar and vertical perfusion stand.

• Unique intelligent syringe recognition technology

• Dynamically display pressure

• The user defines the syringe brands himself

• Stackable boxes

SPECIFICATION

1/ Infusion mode: flow mode, time mode, body weight mode, dose mode, intermittent mode, TIVA, program mode, TPN mode, switching mode, drug library.

2/ Applicable syringes: Different brands of sterile syringes: 2ml, 5ml, 10ml, 20ml, 30ml, 50ml/60ml, including BD, B. Braun, Terumo, Nipro, etc.

3/ Syringe accuracy: ± 2% (after correct calibration of the syringe)

4/ Infusion rate:

2 ml syringe: 0.1 – 150 ml/h

5 ml syringe: 0.1 – 150 ml/h

10 ml syringe: 0.1 – 300 ml/h

increment: 0.01 ml/h

20 ml syringe: 0.1 – 600 ml/h

30 ml syringe: 0.1 – 900 ml/h

50 ml syringe: 0.1 – 1800 ml/h

5/ Volume to infuse: 0∼9999.9 (ml) increment: 0.01 ml/h

6/ Infused volume: 0∼9999.9 (ml)

7/ KVO rate: 0∼5 ml/h adjustable; default value: 0.1 ml/h

8/ Bolus: Manual bolus/Automatic bolus. Bolus rate:

• 10 ml: 100-300 ml/h (default 300 ml)

• 20 ml: 100-600 ml/h (default 600 ml)

• 30 ml: 100-900 ml/h (default 900 ml)

• 50 ml: 100-1500 ml/h (default 1500 ml

9/ Alarms: end of infusion, empty, occlusion, almost finished, low battery, disengaged syringe, no mains power, exhausted battery, malfunction, etc.

10/ Functions:

Sleep function: 1 min – 24 hours adjustable, 13 occlusion levels,

The history records more than 2000 patients.

Can change flow rate and VTBI without stopping the infusion,

compatible with the hospital’s HIS system,

WIFI connection to central monitoring system

11/ Power supply: DC: 12 ± 1.2 V; AC: 100∼240 V, 50/60 Hz

12/ Power consumption: 25 VA

13/ Nurse call function: optional

14/ Classification: Class I, type CF, resistant to defibrillation

15/ Dimensions: 230* 137* 139 (Length × Width × Height)

16/ Net weight: 1.7 KG

17/ Waterproof level: IP24

18/ Battery: Li_polymer 7.4V 1900Ah, more than 6 hours at 5ml/h

19/ Operating conditions: Temperature: 5°C∼40°C, Relative humidity: 10∼95%, Atmospheric pressure: 86∼106 kPa

20/ Transport conditions: Temperature: -20°C∼60°C, Relative humidity: 10∼95%, Atmospheric pressure: 50∼106 kPa

21/ Storage conditions: Temperature: -20°C∼45°C, Relative humidity: 10∼95%, Atmospheric pressure: 50∼106 kPa

Guaranteed 12 months (standard exchange)